Medical device threat modeling for FDA submissions
Medcrypt does medical device threat modeling for FDA premarket submissions. We model your device against its real architecture in STRIDE or the method your team already uses, map every threat to a mitigation, and hand you the threat model FDA reviewers expect under Section 524B. Former FDA reviewers check it before you file.
Catch the design weaknesses before a pen test does, and let the submission artifact fall out of the work.
Features
Teams don't do this for the regulator.
The act of doing it is the win
Working through your architecture surfaces design weaknesses before a pen test or a field deployment finds them for you. Teams come out of the exercise with a better device, not just a better document. For an implant example, see neurostimulator cybersecurity.
Efficiency is how it scales
Scenarios and attack trees arrive drafted from your architecture instead of starting from a blank page, so one team can cover a whole portfolio without adding headcount to do it.
Compliance is the icing
Because the work is built to recognized methodologies and checked by former FDA reviewers, the submission artifact falls out of it. You do the engineering; the evidence is a by-product.
How we work with your team
Three steps, and your team keeps the last word.
You are not handing the work over. The platform does the drafting and the consistency checking; every judgment call stays with the people who know the device.
Bring the documents you already have.
You bring the architecture documents and system descriptions you already maintain. There is no new format to author first and no modelling tool to learn. Because the model is built from how the device is designed rather than from its source, it surfaces architectural weaknesses a code scan structurally cannot see.
Documents
Source documentStatusArchitectureParsedInterfacesParsedData flowsReadingExtracting assets and data-flow diagramDrafted from your architecture, then checked against itself.
Medcrypt drafts the scenarios and attack trees from that architecture, in the methodology your team already works in. Then it checks its own output: inconsistent scoring, structural gaps, and the mismatches an FDA reviewer tends to flag.
Threat register
IDThreatCheckT-001SClearT-002TScoreT-003IClearT-004EGapNothing lands until your team accepts it.
The run stops for review at every stage, so nothing enters the model until your team approves it. Once you have approved a stage your judgment stands: a later run proposes changes rather than overwriting what you decided. Our former FDA reviewers check the finished model for submission-readiness.
Threat model run
Assets extractedThreats identifiedRisks scoredControls mappedAwaiting reviewTraceability reportRequest changesApprove stage
What you get
What lands in your hands.
Accelerated drafting
- Scenarios and attack trees drafted from your architecture, in the methodology your team already works in.
Accuracy and consistency checks
- Flags inconsistent CVSS scoring, structural gaps, and mismatches with what reviewers expect to see.
Answers in plain language
- Ask questions of FDA cybersecurity guidance, vulnerability data, and threat intelligence without leaving the model.
Submission-ready export
- Structured output that drops into your ISO 14971 and AAMI SW96 templates, so the threat model feeds your security risk assessment rather than sitting beside it.
Medical device threat modeling FAQs
Your own engineers, an outside partner, or both working together. The people who know the device's architecture have to be involved, because the threat model must cover the whole system: the device, its connections, cloud services and how updates reach it. What a reviewer looks at is the model itself. It should be complete, explain its scoping decisions and trace to your risk assessment and testing.
Skill is the usual gap. FDA has issued deficiencies for inadequate threat models, and after working with clients we sometimes find that the staff doing the threat modeling were not trained or skilled for that work. Off-the-shelf threat modeling tools rarely give reviewers what they expect either.
Medcrypt does medical device threat modeling with your team, not instead of it. You bring the architecture documents and system descriptions you already maintain. We draft the scenarios and attack trees in your methodology, your experts approve every stage before it lands, and former FDA reviewers check the finished model for submission readiness before you file.
FDA treats threat modeling as part of the security risk assessment. Its premarket guidance recommends that threat modeling be performed throughout the design process and be inclusive of all medical device system elements. In practice that means the device, its interfaces and connections, cloud services and the update path, with your scoping decisions justified. Section 524B and the guidance expect threat models, security risk assessments and security testing for cyber devices, alongside an SBOM and a plan for monitoring and addressing postmarket vulnerabilities.
The model should identify system risks and mitigations across the whole system, in enough detail for a reviewer to trace each threat to a control and a test. A complete model covers the assets, a data-flow diagram, threat scenarios, risk scores and the mapping from each threat to its mitigation.
Common gaps include missing interfaces, inconsistent scoring and a data flow diagram filed in place of a threat model. See how threat modeling fits the other categories in our breakdown of FDA premarket cybersecurity guidance.
Use a recognized method your team can apply consistently and defend in review. In most cases that is the method your team already works in. Medcrypt drafts threat models in STRIDE or the method your team already uses, so you do not have to retrain engineers or rebuild earlier work before you file.
STRIDE is the common starting point. It walks each part of the architecture through six threat types: spoofing, tampering, repudiation, information disclosure, denial of service and elevation of privilege. Attack trees work alongside it. They show the paths an attacker could take to reach a goal, which helps a reviewer see why each mitigation sits where it does.
Whichever method you choose, keep the scoring consistent. Old scoring like CVSS 2.0 rarely gives reviewers what they expect, and inconsistent CVSS scoring is one of the issues our checks flag. Apply the same scoring from threat model to SBOM to testing to postmarket, so a design risk found in threat modeling keeps its score when it is fixed in development. Treat STRIDE, CVSS and 524B lifecycle evidence as the floor, and build engineering value on top of it.
Reviewers read them as one chain of evidence. Your threat model identifies a risk, your security architecture mitigates it, and your testing proves the mitigation works. FDA expects documentation that traces your security requirements through the threat model, software components, security risks, risk controls and verification testing, so make sure your threat model, risk assessment and test results trace to each other.
Every component in your SBOM is part of the attack surface the threat model covers, and the SBOM has to hold up to review just like the model. Helm, our SBOM and vulnerability management platform, keeps machine-readable SBOMs with end-of-support dates, ranks vulnerabilities by exploit risk and exports VEX and VDR documents.
The threat model should feed your security risk assessment rather than sit beside it. Our output drops into your ISO 14971 and AAMI SW96 templates.
Pen testing comes last in the chain. Derive test objectives from your threat model and architecture, not a generic scan of everything. A penetration test contributes objective evidence, but it does not replace threat modeling. Medcrypt helps refine the threat model and risk assessment that set the scope for independent medical device penetration testing.